Electrical data
Power requirements | DC 7.5 V to 12 V / 300mA |
Max. power consumption | 1.5 W |
Power supply | power adapter |
User interface
Digital input | - |
Ethernet 10/100 Mbit/s | ● |
WiFi (2.4GHz, 802.11 b/g/n, WEP,WPA,WPA2,PSK) | - |
RS485 | ● / x 2 |
Analog input on RJ45 | ● (Australia DRM) |
LCD | 16 x 2 characters |
LED | x 4 |
Communication range
Mechanical data
Dimensions (W / H / D) | 138 / 31 / 87.5 mm |
Weight | 230 g |
Installation | Wall, indoor |
Environmental conditions
Operation | -10℃ to +60℃ / +14℉ to +140℉ |
Storage and shipment | -30℃ to +80℃ / -22℉ to +176℉ |
Relative humidity (non-condensing) | 5% to 95% |
Protection class | IP20 |
General data
ZeverCloud support | ● |
Integrated webserver | ● |
Multi-language support | EN, DE |
Certificates and approvals | CE |
Feature
Number of connected inverters | Max. 5 |
Inverter fault alarm output | ● |
Demand Response Mode (AS4777) | ● |
Active power limit setting | ● |
Zero-export control 1) | ● |
Storage | 5 days |
Firmware update | Ethernet |
● standard
○ optional
- not available
1) With zeversolar approved smart meters
As of December, 2018 / Technical data is subject to revisions.
Electrical data
Power requirements | DC 7.5 V to 12 V / 300 mA |
Max. power consumption | 2.5 W |
Power supply | power adapter |
User interface
Digital input | - |
Ethernet 10/100 Mbit/s | ● |
WiFi (2.4GHz, 802.11 b/g/n, WEP,WPA,WPA2,PSK) | ● |
RS485 | ● / x 2 |
Analog input on RJ45 | ● (Australia DRM) |
Micro USB | ● |
LCD | 16 x 2 characters |
LED | x 4 |
Communication range
Mechanical data
Dimensions (W / H / D) | 138 / 31 / 87.5 mm |
Weight | 260 g |
Installation | Wall, indoor |
Environmental conditions
Operation | -10℃ to +60℃ / +14℉ to +140℉ |
Storage and shipment | -30℃ to +80℃ / -22℉ to +176℉ |
Relative humidity (non-condensing) | 5% to 95% |
Protection class | IP20 |
General data
Solarcloud support | ● |
Integrated webserver | ● |
Multi-language support | EN, DE |
Certificates and approvals | CE |
Feature
Number of connected inverters | Max. 5 |
Inverter fault alarm output | ● |
Demand Response Mode (AS4777) | ● |
Active power limit setting | ● |
Zero-export control 1) | ● |
Storage | 5 days |
Firmware update | Ethernet / WiFi |
● standard
○ optional
- not available
1) With zeversolar approved smart meters
As of December, 2018 / Technical data is subject to revisions.